Direct Plate Line Control Panel

Get A Quote!

Control Panel
Series: F06
Frequency: 50/60
Type: 3, 3R, 4, 4X, 5, or 12 Enclosure
Water Tight/ Dust-Tight
Single Throw Fusible

Direct Plate Line

FED FROM RDH2

MAX FUSE 150 AMP LPS-RK

480V

3PH

3W

Square D Heavy Duty Safety Switch

200 A

600 Vac/V~

600Vdc

DS Direct Plate Line
Flash Hazard Boundary: 20.2in
Incident Energy at 18in: 1.44 cal/cm²
Shock Hazard when cover is removed: 480VAC
Class Glove with Leather Protectors: 00
Limited Approach (Fixed Circuit): 42 in
Restricted Approach: 12 in

Catalog no: H364DS

HP Rating/Capacidad en kW (HP)

Volts

ø Std./

Est

Max./

Max

240V~

1 15 —–
240V~ 3 25

60

480V~

1 25 50
480V~ 3 50

125

600V~

1 30 50
600V~ 3 60

150

250V

40 —–
600V 50

—–

Lug Torque Requirements

Line, Load and Neutral Lugs

Equipment Grounding Lug

Wire Size

Torque lbs-in

Wire Size

Torque

 lbs.-in

250-6

275

14-10

35
8

40

6-4

45
3-2

50

Conduit Entry

 

Size

Stan. Cat

No

Chrome Plated

Cat No

Tight. Torque in lbs.

½”

H050 H050CP 800/

90

¾” H075 H075CP

800/

90

1”

H100 H100CP 1000/

113

1 ¼” H125 H125CP

1000/

113

1 ½”

H150 H150CP 1000/

113

2” H200 H200CP

1600/

181

2 ½”

H250 H250CP 1600/

181

3” H300 H200CP

1600/

181

Category: Tag:

Description

Control Panel
Series: F06
Frequency: 50/60
Type: 3, 3R, 4, 4X, 5, or 12 Enclosure
Water Tight/ Dust-Tight
Single Throw Fusible

Direct Plate Line

FED FROM RDH2

MAX FUSE 150 AMP LPS-RK

480V

3PH

3W

Square D Heavy Duty Safety Switch

200 A

600 Vac/V~

600Vdc

DS Direct Plate Line
Flash Hazard Boundary: 20.2in
Incident Energy at 18in: 1.44 cal/cm²
Shock Hazard when cover is removed: 480VAC
Class Glove with Leather Protectors: 00
Limited Approach (Fixed Circuit): 42 in
Restricted Approach: 12 in

Catalog No: H364DS

HP Rating/Capacidad en kW (HP)

Volts

ø Std./

Est

Max./

Max

240V~

1 15 —–
240V~ 3 25

60

480V~

1 25 50
480V~ 3 50

125

600V~

1 30 50
600V~ 3 60

150

250V

40 —–
600V 50

—–

Lug Torque Requirements

Line, Load and Neutral Lugs

Equipment Grounding Lug

Wire Size

Torque lbs-in Wire Size

Torque

 lbs.-in

250-6

275

14-10

35
8

40

6-4

45
3-2

50

Conduit Entry

 

Size

Stan. Cat

No

Chrome Plated

Cat No

Tight. Torque in lbs.

½”

H050 H050CP 800/

90

¾” H075 H075CP

800/

90

1”

H100 H100CP 1000/

113

1 ¼” H125 H125CP

1000/

113

1 ½”

H150 H150CP 1000/

113

2” H200 H200CP

1600/

181

2 ½”

H250 H250CP 1600/

181

3” H300 H200CP

1600/

181